Del Mar Photonics

 Hatteras-D femtosecond  transient absorption data acquisition system

Hatteras brochure - Request a quote - Custom Femtosecond Transient Absorption Data Acquisition Systems

Femtosecond Transient Absorption Measurements system Hatteras Femtosecond Transient Absorption Measurements system Hatteras.
Future nanostructures and biological nanosystems will take advantage not only of the small dimensions of the objects but of the specific way of interaction between nano-objects. The interactions of building blocks within these nanosystems will be studied and optimized on the femtosecond time scale - says Sergey Egorov, President and CEO of Del Mar Photonics, Inc. Thus we put a lot of our efforts and resources into the development of new Ultrafast Dynamics Tools such as our Femtosecond Transient Absorption Measurements system Hatteras. Whether you want to create a new photovoltaic system that will efficiently convert photon energy in charge separation, or build a molecular complex that will dump photon energy into local heat to kill cancer cells, or create a new fluorescent probe for FRET microscopy, understanding of internal dynamics on femtosecond time scale is utterly important and requires advanced measurement techniques.

 

 

Description

 

 

Hatteras-D femtosecond  transient absorption data acquisition system
request a quote

1. CDP2022i imaging spectrometer, adapted to the detector head and connected to a computer via serial port:
Visible grating: 300 –1700 nm spectral range; 206 nm detection range
Infrared grating: 700 nm – 1900 nm spectral range; 206 nm detection range
Entrance slit is equipped with two fiber leads for probe and reference beams  

2. Spectrometer software

3. Multi channel detector head, with two 1024-pixel extra-deep well NMOS linear image sensors, 25,0 mm x 2.5 mm, 200 nm -1000 nm spectral response (10% of peak), >5800 dynamic range

4. Photodiode for the system synchronization

5. Photodiode for pump power measurements

6. Synchronized chopper for 1:1 to 10:10 chopping ratio

7. Synchronized shutter for 50:50 to 100 :100  chopping ratio

8. Control unit, connected to items 2 – 7, connected to computer via USB port.

8. Data acquisition and chirp correction software

 

2

2.0 – ns optical delay line with 0.78 fs / step

 

3

Installation 1 or 1-2

Laser pulse source with 1 kHz pulse rep. rate is required 

 

3

Hatteras femtosecond  transient absorption pump-probe system, including 1-2  and

all optics and mechanics for pump – probe measurements, assembled on a breadboard with cover box:

femtosecond white light (continuum) generator for probe and reference pulse formation at 400 – 1600 nm; transmission and reflection configurations; optics for fluorescence anisotropy measurements; rotating sample cell assembly; holder for solid samples and thin films; set of selected color and neutral density filters

1 week installation visit is included